SLAC Magnetic Measurements Date: 04-02-2010 Time: 13:00:55 Project: LCLS Device Type: Hall probe Data Type: Serial Number: SENTRON_441 Run Number: 183 Measurement Type: Reference magnet Operator: YL Comment: S/N 13 re-measurement; Run50 5.754518 -0.369292 0.069148 -0.369595 0.000384 -0.369172 5.754043 -0.369177 0.066748 -0.369755 0.000078 -0.369174 Field = -0.368584 Adjusted for T = 19.9300 Field = -0.368558 5.755394 -0.369739 0.062216 -0.369900 0.011825 -0.369647 5.754786 -0.369680 0.064246 -0.369832 0.014251 -0.369773 Field = -0.369187 Adjusted for T = 19.9300 Field = -0.369161 5.755227 -0.369851 0.064221 -0.369842 -0.007247 -0.369882 5.754395 -0.369848 0.064950 -0.369834 0.000409 -0.369846 Field = -0.369246 Adjusted for T = 19.9300 Field = -0.369220 5.754819 -0.369854 0.064059 -0.369852 0.000922 -0.369847 5.754561 -0.369838 0.064964 -0.369839 0.000623 -0.369846 Field = -0.369246 Adjusted for T = 19.9300 Field = -0.369220 5.754919 -0.369837 0.064788 -0.369837 0.000684 -0.369832 5.754788 -0.369837 0.064688 -0.369839 0.000812 -0.369834 Field = -0.369249 Not adjusted for T