SLAC Magnetic Measurements Date: 08-04-2015 Time: 09:41:46 Project: LCLS Magnet Type: Phase_Shifter Magnet Name: Phase_Shifter_Delta Serial Number: Run Number: 3 Measurement Device: 10wire Operator: sda Comment: By integral at 60 mm gap Test Currents for Main (A): 0.00 0.00 0.00 09:42:05 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 09:42:05 X and Y Stages Zeroed 09:42:05 MoveXY Devices: Move Device = ESP300, Read Device = ESP300 09:42:28 Ambient Measurement Device(s) Being Used, type = None 09:42:28 Magnet Voltage Measurement Device(s) Being Used, type = None 09:42:28 Temperature Measurement Device(s) Being Used, type = None 09:42:28 XMAG Device(s) Being Used, type = None 09:42:28 Ambient Measurement Device(s) Being Used, type = None 09:42:46 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 09:42:47 8` Voltage Measurement, V = 0.000000 V 09:42:47 8` Voltage Measurement, V = 0.000000 V 09:42:47 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 09:42:47 Integrated Voltage Measurement... 09:43:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003280 Vs 09:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001616 Vs 09:43:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003243 Vs 09:43:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001574 Vs 09:44:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003404 Vs 09:44:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001435 Vs 09:44:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003636 Vs 09:44:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001320 Vs 09:44:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003565 Vs 09:45:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001295 Vs 09:45:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002437 +- 0.000000025 Vs 09:45:13 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000002437 +- 0.000000025 Vs FI1 = -0.00006092 +- 0.00000061 Tm 09:45:20 8` Voltage Measurement, V = 0.000000 V 09:45:20 8` Voltage Measurement, V = 0.000000 V 09:45:20 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 09:45:20 Integrated Voltage Measurement... 09:51:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003427 Vs 09:52:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001333 Vs 09:52:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003522 Vs 09:52:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001240 Vs 09:52:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003482 Vs 09:53:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001368 Vs 09:53:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003420 Vs 09:53:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001489 Vs 09:53:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003382 Vs 09:54:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001521 Vs 09:54:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002418 +- 0.000000032 Vs 09:54:06 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000002418 +- 0.000000032 Vs FI1 = -0.00006046 +- 0.00000081 Tm 09:54:14 8` Voltage Measurement, V = 0.000000 V 09:54:14 8` Voltage Measurement, V = 0.000000 V 09:54:14 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 09:54:14 Integrated Voltage Measurement... 09:54:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003709 Vs 09:54:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001244 Vs 09:55:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003455 Vs 09:55:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001672 Vs 09:55:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003161 Vs 09:55:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001551 Vs 09:56:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003276 Vs 09:56:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001774 Vs 09:56:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003205 Vs 09:56:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001774 Vs 09:56:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002482 +- 0.000000070 Vs 09:56:50 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000002482 +- 0.000000070 Vs FI1 = -0.00006205 +- 0.00000175 Tm 09:56:57 Integrated Voltage Measurement... 09:57:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001905 Vs 09:57:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000705 Vs 09:57:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001871 Vs 09:57:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000524 Vs 09:57:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001867 Vs 09:57:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000688 Vs 09:57:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001883 Vs 09:57:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000523 Vs 09:58:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001987 Vs 09:58:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000410 Vs 09:58:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001236 +- 0.000000046 Vs 09:58:10 Second Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001236 +- 0.000000046 Vs FI2 = -0.00001638 +- 0.00000061 Tm 09:58:37 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m