SLAC Magnetic Measurements Date: 08-03-2015 Time: 17:10:37 Project: LCLS Magnet Type: Phase_Shifter Magnet Name: Phase_Shifter_Delta Serial Number: Run Number: 2 Measurement Device: 10wire Operator: sda Comment: By integral at 70 mm gap. Test Currents for Main (A): 0.00 0.00 0.00 17:10:56 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:10:56 X and Y Stages Zeroed 17:10:56 MoveXY Devices: Move Device = ESP300, Read Device = ESP300 17:11:19 Ambient Measurement Device(s) Being Used, type = None 17:11:19 Magnet Voltage Measurement Device(s) Being Used, type = None 17:11:19 Temperature Measurement Device(s) Being Used, type = None 17:11:19 XMAG Device(s) Being Used, type = None 17:11:19 Ambient Measurement Device(s) Being Used, type = None 17:11:38 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:11:38 8` Voltage Measurement, V = 0.000000 V 17:11:38 8` Voltage Measurement, V = 0.000000 V 17:11:38 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 17:11:38 Integrated Voltage Measurement... 17:11:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003143 Vs 17:12:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001669 Vs 17:12:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002836 Vs 17:12:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000002084 Vs 17:12:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003075 Vs 17:13:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001578 Vs 17:13:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002838 Vs 17:13:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001785 Vs 17:13:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002673 Vs 17:14:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001750 Vs 17:14:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002343 +- 0.000000085 Vs 17:14:04 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000002343 +- 0.000000085 Vs FI1 = -0.00005858 +- 0.00000212 Tm 17:14:11 8` Voltage Measurement, V = 0.000000 V 17:14:11 8` Voltage Measurement, V = 0.000000 V 17:14:11 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 17:14:11 Integrated Voltage Measurement... 17:14:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003337 Vs 17:14:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001343 Vs 17:14:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003465 Vs 17:15:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001315 Vs 17:15:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003118 Vs 17:15:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001699 Vs 17:15:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003209 Vs 17:16:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001590 Vs 17:16:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002938 Vs 17:16:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000002066 Vs 17:16:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002408 +- 0.000000053 Vs 17:16:37 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000002408 +- 0.000000053 Vs FI1 = -0.00006020 +- 0.00000132 Tm 17:16:44 8` Voltage Measurement, V = 0.000000 V 17:16:44 8` Voltage Measurement, V = 0.000000 V 17:16:45 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 17:16:45 Integrated Voltage Measurement... 17:16:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003059 Vs 17:17:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001330 Vs 17:17:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003649 Vs 17:17:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000945 Vs 17:17:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003603 Vs 17:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001134 Vs 17:18:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003253 Vs 17:18:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001461 Vs 17:18:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000003072 Vs 17:19:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001746 Vs 17:19:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000002325 +- 0.000000074 Vs 17:19:11 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000002325 +- 0.000000074 Vs FI1 = -0.00005813 +- 0.00000186 Tm 17:19:36 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m