SLAC Magnetic Measurements Date: 09-10-2015 Time: 16:46:38 Project: LCLS Magnet Type: Phase_Shifter Magnet Name: Phase_Shifter_Delta Serial Number: Run Number: 68 Measurement Device: 10wire Operator: sda Comment: By integral at 20 mm gap with shims to correct gap dependence. Shim locations switched to opposite positions. Test Currents for Main (A): 0.00 0.00 0.00 16:46:48 MoveXY Devices: Move Device = ESP300, Read Device = ESP300 16:47:04 Ambient Measurement Device(s) Being Used, type = None 16:47:04 Magnet Voltage Measurement Device(s) Being Used, type = None 16:47:05 Temperature Measurement Device(s) Being Used, type = None 16:47:05 XMAG Device(s) Being Used, type = None 16:47:06 Ambient Measurement Device(s) Being Used, type = None 16:47:24 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 16:47:24 \ßkh Voltage Measurement, V = 0.000000 V 16:47:24 \ßkh Voltage Measurement, V = 0.000000 V 16:47:25 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 16:47:25 Integrated Voltage Measurement... 16:47:40 Voltage Offset Correction: v_off_ini = 0.000003492 V, v_off_fin = 0.000000298 V 16:47:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001032 Vs 16:47:55 Voltage Offset Correction: v_off_ini = 0.000003959 V, v_off_fin = 0.000005926 V 16:47:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001324 Vs 16:48:10 Voltage Offset Correction: v_off_ini = 0.000003961 V, v_off_fin = 0.000001062 V 16:48:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001094 Vs 16:48:25 Voltage Offset Correction: v_off_ini = 0.000004059 V, v_off_fin = 0.000005841 V 16:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001330 Vs 16:48:40 Voltage Offset Correction: v_off_ini = 0.000003590 V, v_off_fin = 0.000001812 V 16:48:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001295 Vs 16:48:54 Voltage Offset Correction: v_off_ini = 0.000003251 V, v_off_fin = 0.000005163 V 16:48:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001449 Vs 16:49:09 Voltage Offset Correction: v_off_ini = 0.000003390 V, v_off_fin = 0.000001702 V 16:49:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001315 Vs 16:49:24 Voltage Offset Correction: v_off_ini = 0.000002391 V, v_off_fin = 0.000004254 V 16:49:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001519 Vs 16:49:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001295 +- 0.000000102 Vs 16:49:24 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001295 +- 0.000000102 Vs FI1 = -0.00003236 +- 0.00000254 Tm 16:49:31 Integrated Voltage Measurement... 16:49:41 Voltage Offset Correction: v_off_ini = 0.000002051 V, v_off_fin = -0.000001664 V 16:49:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000798 Vs 16:49:48 Voltage Offset Correction: v_off_ini = 0.000002498 V, v_off_fin = 0.000004323 V 16:49:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000021 Vs 16:49:55 Voltage Offset Correction: v_off_ini = 0.000002521 V, v_off_fin = -0.000001785 V 16:49:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000743 Vs 16:50:02 Voltage Offset Correction: v_off_ini = 0.000002677 V, v_off_fin = 0.000004764 V 16:50:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000275 Vs 16:50:09 Voltage Offset Correction: v_off_ini = 0.000002844 V, v_off_fin = 0.000001940 V 16:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000096 Vs 16:50:16 Voltage Offset Correction: v_off_ini = 0.000002733 V, v_off_fin = 0.000004774 V 16:50:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000200 Vs 16:50:23 Voltage Offset Correction: v_off_ini = 0.000003115 V, v_off_fin = 0.000002804 V 16:50:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000171 Vs 16:50:30 Voltage Offset Correction: v_off_ini = 0.000003444 V, v_off_fin = 0.000004720 V 16:50:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000269 Vs 16:50:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000249 +- 0.000000204 Vs 16:50:30 Second Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = 0.000000249 +- 0.000000204 Vs FI2 = 0.00000380 +- 0.00000311 Tm 16:50:37 \ßkh Voltage Measurement, V = 0.000000 V 16:50:37 \ßkh Voltage Measurement, V = 0.000000 V 16:50:38 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 16:50:38 Integrated Voltage Measurement... 16:50:53 Voltage Offset Correction: v_off_ini = 0.000004036 V, v_off_fin = 0.000001736 V 16:50:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001290 Vs 16:51:08 Voltage Offset Correction: v_off_ini = 0.000003802 V, v_off_fin = 0.000005271 V 16:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001169 Vs 16:51:23 Voltage Offset Correction: v_off_ini = 0.000003896 V, v_off_fin = 0.000001958 V 16:51:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001291 Vs 16:51:37 Voltage Offset Correction: v_off_ini = 0.000003322 V, v_off_fin = 0.000005619 V 16:51:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001253 Vs 16:51:52 Voltage Offset Correction: v_off_ini = 0.000003122 V, v_off_fin = 0.000001084 V 16:51:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001227 Vs 16:52:07 Voltage Offset Correction: v_off_ini = 0.000002677 V, v_off_fin = 0.000005040 V 16:52:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001369 Vs 16:52:22 Voltage Offset Correction: v_off_ini = 0.000003247 V, v_off_fin = 0.000001601 V 16:52:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001338 Vs 16:52:37 Voltage Offset Correction: v_off_ini = 0.000002985 V, v_off_fin = 0.000004404 V 16:52:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001489 Vs 16:52:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001303 +- 0.000000068 Vs 16:52:37 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001303 +- 0.000000068 Vs FI1 = -0.00003258 +- 0.00000171 Tm 16:52:44 \ßkh Voltage Measurement, V = 0.000000 V 16:52:45 \ßkh Voltage Measurement, V = 0.000000 V 16:52:45 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 16:52:45 Integrated Voltage Measurement... 16:53:00 Voltage Offset Correction: v_off_ini = 0.000002930 V, v_off_fin = 0.000001090 V 16:53:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001190 Vs 16:53:15 Voltage Offset Correction: v_off_ini = 0.000003589 V, v_off_fin = 0.000005493 V 16:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001507 Vs 16:53:29 Voltage Offset Correction: v_off_ini = 0.000002932 V, v_off_fin = 0.000000146 V 16:53:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000919 Vs 16:53:44 Voltage Offset Correction: v_off_ini = 0.000002967 V, v_off_fin = 0.000005026 V 16:53:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001503 Vs 16:53:59 Voltage Offset Correction: v_off_ini = 0.000002993 V, v_off_fin = 0.000001262 V 16:53:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001282 Vs 16:54:14 Voltage Offset Correction: v_off_ini = 0.000003518 V, v_off_fin = 0.000005607 V 16:54:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001489 Vs 16:54:29 Voltage Offset Correction: v_off_ini = 0.000003621 V, v_off_fin = 0.000001056 V 16:54:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001156 Vs 16:54:44 Voltage Offset Correction: v_off_ini = 0.000003469 V, v_off_fin = 0.000005469 V 16:54:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001282 Vs 16:54:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001291 +- 0.000000077 Vs 16:54:44 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001291 +- 0.000000077 Vs FI1 = -0.00003227 +- 0.00000193 Tm 16:55:09 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m