SLAC Magnetic Measurements Date: 09-10-2015 Time: 16:26:56 Project: LCLS Magnet Type: Phase_Shifter Magnet Name: Phase_Shifter_Delta Serial Number: Run Number: 66 Measurement Device: 10wire Operator: sda Comment: By integral at 40 mm gap with shims to correct gap dependence. Shim locations switched to opposite positions. Test Currents for Main (A): 0.00 0.00 0.00 16:27:07 MoveXY Devices: Move Device = ESP300, Read Device = ESP300 16:27:22 Ambient Measurement Device(s) Being Used, type = None 16:27:22 Magnet Voltage Measurement Device(s) Being Used, type = None 16:27:22 Temperature Measurement Device(s) Being Used, type = None 16:27:22 XMAG Device(s) Being Used, type = None 16:27:22 Ambient Measurement Device(s) Being Used, type = None 16:27:41 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 16:27:41 \ßkh Voltage Measurement, V = 0.000000 V 16:27:41 \ßkh Voltage Measurement, V = 0.000000 V 16:27:41 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 16:27:41 Integrated Voltage Measurement... 16:27:56 Voltage Offset Correction: v_off_ini = 0.000003387 V, v_off_fin = 0.000000940 V 16:27:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000868 Vs 16:28:11 Voltage Offset Correction: v_off_ini = 0.000003775 V, v_off_fin = 0.000005566 V 16:28:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001080 Vs 16:28:27 Voltage Offset Correction: v_off_ini = 0.000004234 V, v_off_fin = 0.000002169 V 16:28:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000939 Vs 16:28:43 Voltage Offset Correction: v_off_ini = 0.000004636 V, v_off_fin = 0.000006299 V 16:28:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000876 Vs 16:28:58 Voltage Offset Correction: v_off_ini = 0.000004844 V, v_off_fin = 0.000002887 V 16:28:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000953 Vs 16:29:12 Voltage Offset Correction: v_off_ini = 0.000005208 V, v_off_fin = 0.000007217 V 16:29:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001010 Vs 16:29:27 Voltage Offset Correction: v_off_ini = 0.000005506 V, v_off_fin = 0.000003621 V 16:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001130 Vs 16:29:42 Voltage Offset Correction: v_off_ini = 0.000005560 V, v_off_fin = 0.000007844 V 16:29:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001216 Vs 16:29:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001009 +- 0.000000099 Vs 16:29:43 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001009 +- 0.000000099 Vs FI1 = -0.00002523 +- 0.00000248 Tm 16:29:50 Integrated Voltage Measurement... 16:30:00 Voltage Offset Correction: v_off_ini = 0.000005270 V, v_off_fin = 0.000001432 V 16:30:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000707 Vs 16:30:07 Voltage Offset Correction: v_off_ini = 0.000005362 V, v_off_fin = 0.000006801 V 16:30:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000017 Vs 16:30:14 Voltage Offset Correction: v_off_ini = 0.000005216 V, v_off_fin = 0.000004451 V 16:30:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000032 Vs 16:30:21 Voltage Offset Correction: v_off_ini = 0.000003962 V, v_off_fin = 0.000005875 V 16:30:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000314 Vs 16:30:28 Voltage Offset Correction: v_off_ini = 0.000003451 V, v_off_fin = 0.000002424 V 16:30:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000012 Vs 16:30:35 Voltage Offset Correction: v_off_ini = 0.000003891 V, v_off_fin = 0.000005721 V 16:30:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000194 Vs 16:30:42 Voltage Offset Correction: v_off_ini = 0.000003275 V, v_off_fin = 0.000000566 V 16:30:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000516 Vs 16:30:49 Voltage Offset Correction: v_off_ini = 0.000001385 V, v_off_fin = 0.000004043 V 16:30:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000085 Vs 16:30:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000227 +- 0.000000108 Vs 16:30:49 Second Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = 0.000000227 +- 0.000000108 Vs FI2 = 0.00000345 +- 0.00000164 Tm 16:30:56 \ßkh Voltage Measurement, V = 0.000000 V 16:30:56 \ßkh Voltage Measurement, V = 0.000000 V 16:30:56 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 16:30:56 Integrated Voltage Measurement... 16:31:11 Voltage Offset Correction: v_off_ini = 0.000003730 V, v_off_fin = 0.000002200 V 16:31:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001182 Vs 16:31:26 Voltage Offset Correction: v_off_ini = 0.000004044 V, v_off_fin = 0.000006412 V 16:31:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000819 Vs 16:31:41 Voltage Offset Correction: v_off_ini = 0.000004742 V, v_off_fin = 0.000002082 V 16:31:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001051 Vs 16:31:56 Voltage Offset Correction: v_off_ini = 0.000003379 V, v_off_fin = 0.000005352 V 16:31:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001051 Vs 16:32:11 Voltage Offset Correction: v_off_ini = 0.000003029 V, v_off_fin = 0.000001890 V 16:32:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001255 Vs 16:32:26 Voltage Offset Correction: v_off_ini = 0.000003031 V, v_off_fin = 0.000005050 V 16:32:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000969 Vs 16:32:40 Voltage Offset Correction: v_off_ini = 0.000002978 V, v_off_fin = 0.000002031 V 16:32:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001199 Vs 16:32:55 Voltage Offset Correction: v_off_ini = 0.000002827 V, v_off_fin = 0.000004722 V 16:32:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000935 Vs 16:32:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001058 +- 0.000000040 Vs 16:32:55 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001058 +- 0.000000040 Vs FI1 = -0.00002644 +- 0.00000100 Tm 16:33:03 \ßkh Voltage Measurement, V = 0.000000 V 16:33:03 \ßkh Voltage Measurement, V = 0.000000 V 16:33:03 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 16:33:03 Integrated Voltage Measurement... 16:33:18 Voltage Offset Correction: v_off_ini = 0.000003529 V, v_off_fin = 0.000001904 V 16:33:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001158 Vs 16:33:32 Voltage Offset Correction: v_off_ini = 0.000003484 V, v_off_fin = 0.000006031 V 16:33:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000756 Vs 16:33:47 Voltage Offset Correction: v_off_ini = 0.000001218 V, v_off_fin = 0.000001387 V 16:33:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001168 Vs 16:34:02 Voltage Offset Correction: v_off_ini = 0.000003371 V, v_off_fin = 0.000005093 V 16:34:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001112 Vs 16:34:17 Voltage Offset Correction: v_off_ini = 0.000002876 V, v_off_fin = 0.000000262 V 16:34:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000918 Vs 16:34:32 Voltage Offset Correction: v_off_ini = 0.000002505 V, v_off_fin = 0.000004534 V 16:34:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001215 Vs 16:34:47 Voltage Offset Correction: v_off_ini = 0.000002017 V, v_off_fin = -0.000000051 V 16:34:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000969 Vs 16:35:01 Voltage Offset Correction: v_off_ini = 0.000001917 V, v_off_fin = 0.000003701 V 16:35:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001005 Vs 16:35:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001037 +- 0.000000071 Vs 16:35:02 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001037 +- 0.000000071 Vs FI1 = -0.00002594 +- 0.00000179 Tm 16:35:27 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m