SLAC Magnetic Measurements Date: 09-03-2015 Time: 21:36:59 Project: LCLS Magnet Type: Phase_Shifter Magnet Name: Phase_Shifter_Delta Serial Number: Run Number: 30 Measurement Device: 10wire Operator: sda Comment: By integral at 14 mm gap with shims to correct gap dependence. Test Currents for Main (A): 0.00 0.00 0.00 21:37:16 X and Y Stages Zeroed 21:37:16 MoveXY Devices: Move Device = ESP300, Read Device = ESP300 21:37:38 Ambient Measurement Device(s) Being Used, type = None 21:37:39 Magnet Voltage Measurement Device(s) Being Used, type = None 21:37:39 Temperature Measurement Device(s) Being Used, type = None 21:37:39 XMAG Device(s) Being Used, type = None 21:37:39 Ambient Measurement Device(s) Being Used, type = None 21:37:57 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 21:37:57 8` Voltage Measurement, V = 0.000000 V 21:37:57 8` Voltage Measurement, V = 0.000000 V 21:37:58 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 21:37:58 Integrated Voltage Measurement... 21:38:12 Voltage Offset Correction: v_off_ini = 0.000001013 V, v_off_fin = 0.000001485 V 21:38:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001460 Vs 21:38:27 Voltage Offset Correction: v_off_ini = 0.000000888 V, v_off_fin = 0.000002507 V 21:38:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001105 Vs 21:38:42 Voltage Offset Correction: v_off_ini = 0.000000682 V, v_off_fin = 0.000001193 V 21:38:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001656 Vs 21:38:57 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = 0.000000449 V 21:38:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001073 Vs 21:39:12 Voltage Offset Correction: v_off_ini = -0.000001220 V, v_off_fin = -0.000002364 V 21:39:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001114 Vs 21:39:27 Voltage Offset Correction: v_off_ini = 0.000000836 V, v_off_fin = -0.000000771 V 21:39:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001869 Vs 21:39:41 Voltage Offset Correction: v_off_ini = -0.000000248 V, v_off_fin = 0.000000647 V 21:39:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001938 Vs 21:39:56 Voltage Offset Correction: v_off_ini = -0.000001038 V, v_off_fin = 0.000002736 V 21:39:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000329 Vs 21:39:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001318 +- 0.000000130 Vs 21:39:56 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001318 +- 0.000000130 Vs FI1 = -0.00003296 +- 0.00000325 Tm 21:40:03 Integrated Voltage Measurement... 21:40:13 Voltage Offset Correction: v_off_ini = -0.000001506 V, v_off_fin = -0.000002400 V 21:40:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000154 Vs 21:40:20 Voltage Offset Correction: v_off_ini = -0.000001730 V, v_off_fin = -0.000001342 V 21:40:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000178 Vs 21:40:27 Voltage Offset Correction: v_off_ini = -0.000001735 V, v_off_fin = -0.000003314 V 21:40:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000673 Vs 21:40:34 Voltage Offset Correction: v_off_ini = -0.000001458 V, v_off_fin = -0.000001436 V 21:40:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000181 Vs 21:40:41 Voltage Offset Correction: v_off_ini = -0.000000389 V, v_off_fin = -0.000000989 V 21:40:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000423 Vs 21:40:48 Voltage Offset Correction: v_off_ini = 0.000000649 V, v_off_fin = 0.000001457 V 21:40:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000466 Vs 21:40:55 Voltage Offset Correction: v_off_ini = 0.000000212 V, v_off_fin = 0.000000456 V 21:40:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000201 Vs 21:41:02 Voltage Offset Correction: v_off_ini = -0.000000784 V, v_off_fin = -0.000000747 V 21:41:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000202 Vs 21:41:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000259 +- 0.000000186 Vs 21:41:02 Second Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = 0.000000259 +- 0.000000186 Vs FI2 = 0.00000395 +- 0.00000284 Tm 21:41:09 8` Voltage Measurement, V = 0.000000 V 21:41:09 8` Voltage Measurement, V = 0.000000 V 21:41:09 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 21:41:10 Integrated Voltage Measurement... 21:41:24 Voltage Offset Correction: v_off_ini = -0.000000732 V, v_off_fin = -0.000000308 V 21:41:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001655 Vs 21:41:39 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = 0.000000263 V 21:41:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001096 Vs 21:41:54 Voltage Offset Correction: v_off_ini = -0.000001201 V, v_off_fin = -0.000000634 V 21:41:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001681 Vs 21:42:09 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = -0.000003213 V 21:42:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001983 Vs 21:42:23 Voltage Offset Correction: v_off_ini = -0.000001666 V, v_off_fin = -0.000004517 V 21:42:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000820 Vs 21:42:38 Voltage Offset Correction: v_off_ini = -0.000001611 V, v_off_fin = -0.000000016 V 21:42:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001192 Vs 21:42:53 Voltage Offset Correction: v_off_ini = -0.000002267 V, v_off_fin = -0.000002976 V 21:42:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001317 Vs 21:43:08 Voltage Offset Correction: v_off_ini = -0.000002684 V, v_off_fin = -0.000002051 V 21:43:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001406 Vs 21:43:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001394 +- 0.000000293 Vs 21:43:08 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001394 +- 0.000000293 Vs FI1 = -0.00003484 +- 0.00000733 Tm 21:43:15 Integrated Voltage Measurement... 21:43:25 Voltage Offset Correction: v_off_ini = -0.000002955 V, v_off_fin = -0.000003012 V 21:43:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000301 Vs 21:43:32 Voltage Offset Correction: v_off_ini = -0.000002133 V, v_off_fin = -0.000001957 V 21:43:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000100 Vs 21:43:39 Voltage Offset Correction: v_off_ini = -0.000002282 V, v_off_fin = -0.000002697 V 21:43:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000201 Vs 21:43:46 Voltage Offset Correction: v_off_ini = -0.000002689 V, v_off_fin = -0.000001677 V 21:43:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000198 Vs 21:43:53 Voltage Offset Correction: v_off_ini = -0.000001967 V, v_off_fin = -0.000003277 V 21:43:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000480 Vs 21:44:00 Voltage Offset Correction: v_off_ini = -0.000002581 V, v_off_fin = -0.000001973 V 21:44:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000503 Vs 21:44:07 Voltage Offset Correction: v_off_ini = -0.000002404 V, v_off_fin = -0.000003378 V 21:44:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000389 Vs 21:44:14 Voltage Offset Correction: v_off_ini = -0.000002536 V, v_off_fin = -0.000001413 V 21:44:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000367 Vs 21:44:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000292 +- 0.000000152 Vs 21:44:14 Second Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = 0.000000292 +- 0.000000152 Vs FI2 = 0.00000446 +- 0.00000232 Tm 21:44:21 8` Voltage Measurement, V = 0.000000 V 21:44:21 8` Voltage Measurement, V = 0.000000 V 21:44:21 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 21:44:21 Integrated Voltage Measurement... 21:44:36 Voltage Offset Correction: v_off_ini = -0.000001815 V, v_off_fin = -0.000002256 V 21:44:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001367 Vs 21:44:51 Voltage Offset Correction: v_off_ini = -0.000000513 V, v_off_fin = -0.000000781 V 21:44:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001694 Vs 21:45:06 Voltage Offset Correction: v_off_ini = -0.000000948 V, v_off_fin = -0.000002007 V 21:45:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001386 Vs 21:45:20 Voltage Offset Correction: v_off_ini = -0.000000797 V, v_off_fin = 0.000000678 V 21:45:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001332 Vs 21:45:35 Voltage Offset Correction: v_off_ini = -0.000000811 V, v_off_fin = -0.000001790 V 21:45:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001297 Vs 21:45:50 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000001462 V 21:45:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001550 Vs 21:46:05 Voltage Offset Correction: v_off_ini = -0.000001179 V, v_off_fin = -0.000003501 V 21:46:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000000911 Vs 21:46:20 Voltage Offset Correction: v_off_ini = -0.000001095 V, v_off_fin = 0.000000464 V 21:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000001069 Vs 21:46:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = -0.000001326 +- 0.000000203 Vs 21:46:20 First Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = -0.000001326 +- 0.000000203 Vs FI1 = -0.00003314 +- 0.00000508 Tm 21:46:27 Integrated Voltage Measurement... 21:46:37 Voltage Offset Correction: v_off_ini = 0.000000098 V, v_off_fin = -0.000001671 V 21:46:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000658 Vs 21:46:44 Voltage Offset Correction: v_off_ini = 0.000000047 V, v_off_fin = -0.000000861 V 21:46:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000040 Vs 21:46:51 Voltage Offset Correction: v_off_ini = -0.000000347 V, v_off_fin = -0.000000685 V 21:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000236 Vs 21:46:58 Voltage Offset Correction: v_off_ini = -0.000000897 V, v_off_fin = 0.000000458 V 21:46:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000403 Vs 21:47:05 Voltage Offset Correction: v_off_ini = -0.000001290 V, v_off_fin = -0.000002729 V 21:47:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000434 Vs 21:47:12 Voltage Offset Correction: v_off_ini = -0.000001789 V, v_off_fin = -0.000000657 V 21:47:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = -0.000000444 Vs 21:47:19 Voltage Offset Correction: v_off_ini = -0.000001502 V, v_off_fin = -0.000001250 V 21:47:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000155 Vs 21:47:26 Voltage Offset Correction: v_off_ini = -0.000000753 V, v_off_fin = -0.000000464 V 21:47:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0040000 m VT = 0.000000110 Vs 21:47:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0040000 m VT = 0.000000272 +- 0.000000153 Vs 21:47:26 Second Field Integral, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0040000 m, Nturns = 10.0 VT = 0.000000272 +- 0.000000153 Vs FI2 = 0.00000416 +- 0.00000233 Tm 21:47:51 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m