SLAC Magnetic Measurements Date: 08-25-2015 Time: 10:00:47 Project: LCLS Magnet Type: Phase_Shifter Magnet Name: Phase_Shifter_Delta Serial Number: Run Number: 18 Measurement Device: 10wire Operator: sda Comment: Bx integral sign check. Integrals should be positive. Field is pointing left. Test Currents for Main (A): 0.00 Bx 2nd Field Integral Distance the wire was moved = 0.004000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 Main +/- sigma X Y Integral sigIntegral (A) (m) (m) (Tm^2) -------------+--------- ----------- ----------- ------------+------------ 0.0000 0.0000 0.000000 0.000000 -0.002755 0.000003