SLAC Magnetic Measurements Date: 08-25-2015 Time: 10:12:24 Project: LCLS Magnet Type: Phase_Shifter Magnet Name: Phase_Shifter_Delta Serial Number: Run Number: 19 Measurement Device: 10wire Operator: sda Comment: Bx integral sign check. Integrals should be positive. Field is pointing left. Test Currents for Main (A): 0.00 Bx 1st Field Integral Distance the wire was moved = 0.004000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 Main +/- sigma X Y Integral sigIntegral (A) (m) (m) (Tm) -------------+--------- ----------- ----------- ------------+------------ 0.0000 0.0000 0.000000 0.000000 0.005779 0.000014