Project: ILC Magnet Type: Dipole Magnet Name: ECBEND01 Serial Number: 1 Aligned probe so Bx and Bz are ~ 0 gauss. Bx seems to act properly, in that a slight change of roll zeros the Bx field. Bz similiarly in that the probe needs to be pitched 1.18 degrees (probe moved 9.95 mm in y with a lever arm of 48 cm).