Quadrupole Magnet Checks

 

60Q-102

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 2/21/2002

 

 60Q-102

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-11.3272

 11.1189

 16.2003

 

 

 

 

 

 

 

TB2

 11.3026

 11.1261

 16.2057

 

 

 

 

 

 

 

TB3

-11.3242

-11.1556

 16.2036

 

 

Offset:

 

 

 

 

TB4

 11.3032

-11.1373

 16.2029

 

 

0.0000

 inches

 

 

 

TB5

-10.3345

-15.1987

-4.7223

 

 

 

 

 

 

 

TB6

 11.2030

-15.1999

-4.7195

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0001

 0.0006

Position 2

-0.0001

 0.0007

Position 3

 0.0015

 0.0017

Position 4

 0.0013

 0.0011

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

-0.0002

 0.0011

Position 1 (2nd check)

-0.0002

 0.0006

Position 1 (3rd check)

-0.0003

 0.0010

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.024

Loc 1: 1.025

Loc 2: 1.024

Loc 2: 1.025

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 60Q-102

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 2/21/2002    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
     

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-11.3272

11.1189

16.2003

TB2

11.3026

11.1261

16.2057

TB3

-11.3242

-11.1556

16.2036

TB4

11.3032

-11.1373

16.2029

TB5

-10.3345

-15.1987

-4.7223

TB6

11.2030

-15.1999

-4.7195

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5012

10.5 in

 14.8050

14.8 in

R2

 10.4996

10.5 in

 14.8091

14.8 in

R3

-10.4995

-10.5 in

 14.8075

14.8 in

R4

-10.5031

-10.5 in

 14.8065

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0000

 0.0001

Position 3

 0.0016

 0.0011

Position 4

 0.0014

 0.0005

Approval __________________