Quadrupole Magnet Checks

 

60Q-097

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 2/19/2002

 

 60Q-097

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-11.2815

 11.1391

 16.2016

 

 

 

 

 

 

 

TB2

 11.3362

 11.1729

 16.2070

 

 

 

 

 

 

 

TB3

-11.2873

-11.1873

 16.2044

 

 

Offset:

 

 

 

 

TB4

 11.3298

-11.1314

 16.2012

 

 

0.0000

 inches

 

 

 

TB5

-10.3219

-15.2048

-4.7011

 

 

 

 

 

 

 

TB6

 11.1985

-15.2005

-4.7177

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0001

 0.0004

Position 2

-0.0001

 0.0016

Position 3

-0.0002

 0.0006

Position 4

-0.0001

-0.0001

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

-0.0002

-0.0016

Position 1 (2nd check)

 0.0006

-0.0019

Position 1 (3rd check)

-0.0002

-0.0012

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.024

Loc 1: 1.027

Loc 2: 1.025

Loc 2: 1.026

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 60Q-097

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 2/19/2002    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
     

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-11.2815

11.1391

16.2016

TB2

11.3362

11.1729

16.2070

TB3

-11.2873

-11.1873

16.2044

TB4

11.3298

-11.1314

16.2012

TB5

-10.3219

-15.2048

-4.7011

TB6

11.1985

-15.2005

-4.7177

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5002

10.5 in

 14.8072

14.8 in

R2

 10.4963

10.5 in

 14.8078

14.8 in

R3

-10.4989

-10.5 in

 14.8084

14.8 in

R4

-10.5020

-10.5 in

 14.8059

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0000

 0.0011

Position 3

-0.0001

 0.0002

Position 4

-0.0001

-0.0005

Approval __________________