Quadrupole Magnet Checks

 

50Q-095

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 1/3/2002

 

 50Q-095

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Remeasured U/S and D/S 3 piece mandrel position 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-9.4467

 11.2355

 16.2068

 

 

 

 

 

 

 

TB2

 9.4561

 11.2484

 16.2049

 

 

 

 

 

 

 

TB3

-9.4693

-11.2753

 16.2048

 

 

Offset:

 

 

 

 

TB4

 9.4734

-11.2480

 16.2072

 

 

0.0000

 inches

 

 

 

TB5

-8.3317

-15.2010

-4.6954

 

 

 

 

 

 

 

TB6

 9.2149

-15.2042

-4.7114

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0002

 0.0002

Position 2

-0.0019

 0.0019

Position 3

 0.0009

 0.0037

Position 4

 0.0021

 0.0018

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0019

 0.0017

Position 1 (2nd check)

-0.0011

-0.0003

Position 1 (3rd check)

-0.0012

 0.0004

Position 1 (4th check if necc)

-0.0010

 0.0003

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.024

Loc 2: 1.023

Loc 2: 1.024

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 50Q-095

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 1/3/2002    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Remeasured U/S and D/S 3 piece mandrel position 1.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-9.4467

11.2355

16.2068

TB2

9.4561

11.2484

16.2049

TB3

-9.4693

-11.2753

16.2048

TB4

9.4734

-11.2480

16.2072

TB5

-8.3317

-15.2010

-4.6954

TB6

9.2149

-15.2042

-4.7114

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5033

10.5 in

 14.8047

14.8 in

R2

 10.4976

10.5 in

 14.8092

14.8 in

R3

-10.4977

-10.5 in

 14.8111

14.8 in

R4

-10.4944

-10.5 in

 14.8075

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0017

 0.0018

Position 3

 0.0010

 0.0035

Position 4

 0.0023

 0.0017

Approval __________________