Quadrupole Magnet Checks

 

50Q-094

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 1/3/2002

 

 50Q-094

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Remeasured U/S 3 piece mandrel position 1 2 times.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-9.4846

 11.2915

 16.2045

 

 

 

 

 

 

 

TB2

 9.4801

 11.2553

 16.2049

 

 

 

 

 

 

 

TB3

-9.4631

-11.2465

 16.2049

 

 

Offset:

 

 

 

 

TB4

 9.4734

-11.2524

 16.1996

 

 

0.0000

 inches

 

 

 

TB5

-8.3597

-15.2022

-4.6948

 

 

 

 

 

 

 

TB6

 9.2111

-15.2016

-4.7217

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0001

 0.0001

Position 2

 0.0001

 0.0014

Position 3

 0.0024

 0.0028

Position 4

 0.0033

 0.0018

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

-0.0007

-0.0002

Position 1 (2nd check)

 0.0001

-0.0003

Position 1 (3rd check)

 0.0139

 0.0942

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.023

Loc 2: 1.023

Loc 2: 1.022

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 50Q-094

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 1/3/2002    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Remeasured U/S 3 piece mandrel position 1 2 times.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-9.4846

11.2915

16.2045

TB2

9.4801

11.2553

16.2049

TB3

-9.4631

-11.2465

16.2049

TB4

9.4734

-11.2524

16.1996

TB5

-8.3597

-15.2022

-4.6948

TB6

9.2111

-15.2016

-4.7217

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5034

10.5 in

 14.8065

14.8 in

R2

 10.4998

10.5 in

 14.8107

14.8 in

R3

-10.4892

-10.5 in

 14.8164

14.8 in

R4

-10.4995

-10.5 in

 14.8075

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0001

 0.0012

Position 3

 0.0022

 0.0027

Position 4

 0.0032

 0.0017

Approval __________________