Quadrupole
Magnet Checks |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Date: |
|
Magnet: |
|
|
|
Operator(s): |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes: |
|
|
|
|
|
|
|
|
|
|
Remeasured U/S 3 piece mandrel position 1 2
times. |
|
|
||||||
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic
Fiducial Coordinates: (inches) |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fiducial |
Z |
X |
Y |
|
|
|
|
|
|
|
-9.4846 |
11.2915 |
16.2045 |
|
|
|
|
|
|
|
|
9.4801 |
11.2553 |
16.2049 |
|
|
|
|
|
|
|
|
-9.4631 |
-11.2465 |
16.2049 |
|
|
Offset: |
|
|
|
|
|
9.4734 |
-11.2524 |
16.1996 |
|
|
0.0000 |
inches |
|
|
|
|
-8.3597 |
-15.2022 |
-4.6948 |
|
|
|
|
|
|
|
|
9.2111 |
-15.2016 |
-4.7217 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Description: |
|
|
|
|
|
|
|
|
|
|
Fiducial
values based on the measured mechanical center line. |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
Quadrupole
Mechanical Centerline Checks:
Mandrel Check (4 Positions): |
X (in) |
Y (in) |
0.0001 |
0.0001 |
|
0.0001 |
0.0014 |
|
0.0024 |
0.0028 |
|
0.0033 |
0.0018 |
Mandrel Check (Position 1): |
X (in) |
Y (in) |
-0.0007 |
-0.0002 |
|
0.0001 |
-0.0003 |
|
0.0139 |
0.0942 |
|
NA |
NA |
|
NA |
NA |
|
|
Gap Measurements: |
|
Upstream (in) |
Downstream (in) |
Approval __________________
|
Quadrupole Magnet Fiducialization Traveller |
Approval must be obtained before removing the magnet from the test stand. |
Magnetic Measurements Approval by – Jack Tanabe or Tony King. |
IHEP Magnetic Measurements Operator: ____________ Date:_____________ |
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
SLAC Magnetic Measurements Operator: ____________ Date:_____________ |
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
Fiducialization: |
Fiducial – Measured Coordinates |
z |
x |
y |
(in) |
(in) |
(in) |
|
-9.4846 |
11.2915 |
16.2045 |
|
9.4801 |
11.2553 |
16.2049 |
|
-9.4631 |
-11.2465 |
16.2049 |
|
9.4734 |
-11.2524 |
16.1996 |
|
-8.3597 |
-15.2022 |
-4.6948 |
|
9.2111 |
-15.2016 |
-4.7217 |
(For x, y corrected coordinates, use SLAC data if available. If not, use IHEP data.)
Fiducial – Corrected Coordinates |
z |
x |
y |
(in) |
(in) |
(in) |
|
TB1 |
|
|
|
TB2 |
|
|
|
TB3 |
|
|
|
TB4 |
|
|
|
TB5 |
|
|
|
TB6 |
|
|
|
Check Measurements:
Rod |
xmeasured |
xnominal |
ymeasured |
ynominal |
10.5034 |
10.5 in |
14.8065 |
14.8 in |
|
10.4998 |
10.5 in |
14.8107 |
14.8 in |
|
-10.4892 |
-10.5 in |
14.8164 |
14.8 in |
|
-10.4995 |
-10.5 in |
14.8075 |
14.8 in |
Cylinder at Different Positions
Position 1 (x,y)=(0,0) |
x (in) |
y (in) |
-0.0001 |
0.0012 |
|
0.0022 |
0.0027 |
|
0.0032 |
0.0017 |
Approval __________________