Quadrupole Magnet Checks

 

50Q-093

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 11/12/2001

 

 50Q-093

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-9.4290

 11.2417

 16.2027

 

 

 

 

 

 

 

TB2

 9.4758

 11.2433

 16.2048

 

 

 

 

 

 

 

TB3

-9.4401

-11.2431

 16.2065

 

 

Offset:

 

 

 

 

TB4

 9.4485

-11.2480

 16.2028

 

 

0.0000

 inches

 

 

 

TB5

-8.3471

-15.2025

-4.7761

 

 

 

 

 

 

 

TB6

 9.2691

-15.2011

-4.7241

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0000

 0.0001

Position 2

-0.0014

 0.0021

Position 3

 0.0006

 0.0037

Position 4

 0.0012

 0.0015

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

-0.0014

 0.0005

Position 1 (2nd check)

-0.0009

 0.0007

Position 1 (3rd check)

-0.0009

 0.0008

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.023

Loc 2: 1.023

Loc 2: 1.023

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 50Q-093

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 11/12/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
     

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-9.4290

11.2417

16.2027

TB2

9.4758

11.2433

16.2048

TB3

-9.4401

-11.2431

16.2065

TB4

9.4485

-11.2480

16.2028

TB5

-8.3471

-15.2025

-4.7761

TB6

9.2691

-15.2011

-4.7241

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5010

10.5 in

 14.8097

14.8 in

R2

 10.4991

10.5 in

 14.8091

14.8 in

R3

-10.4983

-10.5 in

 14.8118

14.8 in

R4

-10.4999

-10.5 in

 14.8097

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0014

 0.0020

Position 3

 0.0006

 0.0036

Position 4

 0.0012

 0.0014

Approval __________________