Quadrupole Magnet Checks

 

50Q-084

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 11/8/2001

 

 50Q-084

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Remeasured VG2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-9.4574

 11.2464

 16.2020

 

 

 

 

 

 

 

TB2

 9.4476

 11.2571

 16.2056

 

 

 

 

 

 

 

TB3

-9.4304

-11.2359

 16.2037

 

 

Offset:

 

 

 

 

TB4

 9.4479

-11.2410

 16.2005

 

 

0.0000

 inches

 

 

 

TB5

-8.4042

-15.2012

-4.7520

 

 

 

 

 

 

 

TB6

 9.3051

-15.2010

-4.6841

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0001

 0.0003

Position 2

-0.0011

 0.0013

Position 3

 0.0002

 0.0019

Position 4

 0.0017

 0.0015

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0000

 0.0002

Position 1 (2nd check)

-0.0002

 0.0003

Position 1 (3rd check)

 0.0004

-0.0001

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.022

Loc 2: 1.022

Loc 2: 1.022

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 50Q-084

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 11/8/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Remeasured VG2.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-9.4574

11.2464

16.2020

TB2

9.4476

11.2571

16.2056

TB3

-9.4304

-11.2359

16.2037

TB4

9.4479

-11.2410

16.2005

TB5

-8.4042

-15.2012

-4.7520

TB6

9.3051

-15.2010

-4.6841

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.4979

10.5 in

 14.8108

14.8 in

R2

 10.4975

10.5 in

 14.8114

14.8 in

R3

-10.4996

-10.5 in

 14.8105

14.8 in

R4

-10.5018

-10.5 in

 14.8087

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0010

 0.0010

Position 3

 0.0003

 0.0016

Position 4

 0.0018

 0.0012

Approval __________________