Quadrupole
Magnet Checks |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Date: |
|
Magnet: |
|
|
|
Operator(s): |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes: |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic
Fiducial Coordinates: (inches) |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fiducial |
Z |
X |
Y |
|
|
|
|
|
|
|
-9.4574 |
11.2464 |
16.2020 |
|
|
|
|
|
|
|
|
9.4476 |
11.2571 |
16.2056 |
|
|
|
|
|
|
|
|
-9.4304 |
-11.2359 |
16.2037 |
|
|
Offset: |
|
|
|
|
|
9.4479 |
-11.2410 |
16.2005 |
|
|
0.0000 |
inches |
|
|
|
|
-8.4042 |
-15.2012 |
-4.7520 |
|
|
|
|
|
|
|
|
9.3051 |
-15.2010 |
-4.6841 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Description: |
|
|
|
|
|
|
|
|
|
|
Fiducial
values based on the measured mechanical center line. |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
Quadrupole
Mechanical Centerline Checks:
Mandrel Check (4 Positions): |
X (in) |
Y (in) |
-0.0001 |
0.0003 |
|
-0.0011 |
0.0013 |
|
0.0002 |
0.0019 |
|
0.0017 |
0.0015 |
Mandrel Check (Position 1): |
X (in) |
Y (in) |
0.0000 |
0.0002 |
|
-0.0002 |
0.0003 |
|
0.0004 |
-0.0001 |
|
NA |
NA |
|
NA |
NA |
|
|
Gap Measurements: |
|
Upstream (in) |
Downstream (in) |
Approval __________________
|
Quadrupole Magnet Fiducialization Traveller |
Approval must be obtained before removing the magnet from the test stand. |
Magnetic Measurements Approval by – Jack Tanabe or Tony King. |
IHEP Magnetic Measurements Operator: ____________ Date:_____________ |
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
SLAC Magnetic Measurements Operator: ____________ Date:_____________ |
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
Fiducialization: |
Fiducial – Measured Coordinates |
z |
x |
y |
(in) |
(in) |
(in) |
|
-9.4574 |
11.2464 |
16.2020 |
|
9.4476 |
11.2571 |
16.2056 |
|
-9.4304 |
-11.2359 |
16.2037 |
|
9.4479 |
-11.2410 |
16.2005 |
|
-8.4042 |
-15.2012 |
-4.7520 |
|
9.3051 |
-15.2010 |
-4.6841 |
(For x, y corrected coordinates, use SLAC data if available. If not, use IHEP data.)
Fiducial – Corrected Coordinates |
z |
x |
y |
(in) |
(in) |
(in) |
|
TB1 |
|
|
|
TB2 |
|
|
|
TB3 |
|
|
|
TB4 |
|
|
|
TB5 |
|
|
|
TB6 |
|
|
|
Check Measurements:
Rod |
xmeasured |
xnominal |
ymeasured |
ynominal |
10.4979 |
10.5 in |
14.8108 |
14.8 in |
|
10.4975 |
10.5 in |
14.8114 |
14.8 in |
|
-10.4996 |
-10.5 in |
14.8105 |
14.8 in |
|
-10.5018 |
-10.5 in |
14.8087 |
14.8 in |
Cylinder at Different Positions
Position 1 (x,y)=(0,0) |
x (in) |
y (in) |
-0.0010 |
0.0010 |
|
0.0003 |
0.0016 |
|
0.0018 |
0.0012 |
Approval __________________