Quadrupole Magnet Checks

 

50Q-082

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 10/30/2001

 

 50Q-082

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Redid Tip 1,2, and 3.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-9.4549

 11.2311

 16.2018

 

 

 

 

 

 

 

TB2

 9.4568

 11.2227

 16.2067

 

 

 

 

 

 

 

TB3

-9.4323

-11.2184

 16.2016

 

 

Offset:

 

 

 

 

TB4

 9.4474

-11.2539

 16.2050

 

 

0.0000

 inches

 

 

 

TB5

-8.3573

-15.1999

-4.7315

 

 

 

 

 

 

 

TB6

 9.2957

-15.2018

-4.7704

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0001

 0.0001

Position 2

-0.0011

 0.0018

Position 3

 0.0001

 0.0028

Position 4

 0.0010

 0.0012

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

-0.0013

-0.0004

Position 1 (2nd check)

-0.0006

-0.0005

Position 1 (3rd check)

-0.0005

 0.0001

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.024

Loc 1: 1.025

Loc 2: 1.023

Loc 2: 1.024

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 50Q-082

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 10/30/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Redid Tip 1,2, and 3.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-9.4549

11.2311

16.2018

TB2

9.4568

11.2227

16.2067

TB3

-9.4323

-11.2184

16.2016

TB4

9.4474

-11.2539

16.2050

TB5

-8.3573

-15.1999

-4.7315

TB6

9.2957

-15.2018

-4.7704

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.4995

10.5 in

 14.8106

14.8 in

R2

 10.4973

10.5 in

 14.8108

14.8 in

R3

-10.4997

-10.5 in

 14.8101

14.8 in

R4

-10.5007

-10.5 in

 14.8099

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0010

 0.0016

Position 3

 0.0001

 0.0026

Position 4

 0.0011

 0.0011

Approval __________________