Quadrupole Magnet Checks

 

34Q-057

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 12/14/2001

 

 34Q-057

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Corner of magnet near tooling ball # 1 was bumped before setup and Fiducialization.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-6.3042

 11.2426

 16.2009

 

 

 

 

 

 

 

TB2

 6.3207

 11.2451

 16.2022

 

 

 

 

 

 

 

TB3

-6.3224

-11.2480

 16.2020

 

 

Offset:

 

 

 

 

TB4

 6.3080

-11.2610

 16.2011

 

 

0.0000

 inches

 

 

 

TB5

-5.2217

-15.2012

-4.7112

 

 

 

 

 

 

 

TB6

 4.5202

-15.2008

-4.7172

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0001

 0.0001

Position 2

 0.0002

-0.0001

Position 3

 0.0008

-0.0004

Position 4

-0.0002

-0.0006

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

-0.0009

-0.0040

Position 1 (2nd check)

-0.0018

-0.0019

Position 1 (3rd check)

-0.0012

-0.0013

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.024

Loc 2: 1.023

Loc 2: 1.023

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 34Q-057

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 12/14/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Corner of magnet near tooling ball # 1 was bumped before setup and Fiducialization.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-6.3042

11.2426

16.2009

TB2

6.3207

11.2451

16.2022

TB3

-6.3224

-11.2480

16.2020

TB4

6.3080

-11.2610

16.2011

TB5

-5.2217

-15.2012

-4.7112

TB6

4.5202

-15.2008

-4.7172

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5000

10.5 in

 14.8144

14.8 in

R2

 10.4987

10.5 in

 14.8095

14.8 in

R3

-10.5001

-10.5 in

 14.8077

14.8 in

R4

-10.4997

-10.5 in

 14.8073

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0003

-0.0003

Position 3

 0.0008

-0.0006

Position 4

-0.0001

-0.0008

Approval __________________