|
Quadrupole
Magnet Checks |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Date: |
|
Magnet: |
|
|
|
Operator(s): |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes: |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic
Fiducial Coordinates: (inches) |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fiducial |
Z |
X |
Y |
|
|
|
|
|
|
|
-6.3386 |
11.2293 |
16.2061 |
|
|
|
|
|
|
|
|
6.2927 |
11.2450 |
16.2052 |
|
|
|
|
|
|
|
|
-6.2868 |
-11.2456 |
16.2028 |
|
|
Offset: |
|
|
|
|
|
6.3457 |
-11.2493 |
16.1992 |
|
|
0.0000 |
inches |
|
|
|
|
-5.2278 |
-15.2034 |
-4.7148 |
|
|
|
|
|
|
|
|
4.5847 |
-15.2004 |
-4.7162 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Description: |
|
|
|
|
|
|
|
|
|
|
Fiducial
values based on the measured mechanical center line. |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
Quadrupole
Mechanical Centerline Checks:
Mandrel Check (4 Positions): |
X (in) |
Y (in) |
0.0001 |
0.0000 |
|
0.0010 |
-0.0002 |
|
0.0012 |
-0.0002 |
|
0.0003 |
-0.0007 |
Mandrel Check (Position 1): |
X (in) |
Y (in) |
-0.0009 |
-0.0020 |
|
-0.0021 |
-0.0020 |
|
-0.0013 |
-0.0019 |
|
NA |
NA |
|
NA |
NA |
|
|
Gap Measurements: |
|
Upstream (in) |
Downstream (in) |
Approval __________________
|
Quadrupole Magnet Fiducialization Traveller |
Approval must be obtained before removing the magnet from the test stand. |
Magnetic Measurements Approval by – Jack Tanabe or Tony King. |
IHEP Magnetic Measurements Operator: ____________ Date:_____________ |
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
SLAC Magnetic Measurements Operator: ____________ Date:_____________ |
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
Fiducialization: |
Fiducial – Measured Coordinates |
z |
x |
y |
(in) |
(in) |
(in) |
|
-6.3386 |
11.2293 |
16.2061 |
|
6.2927 |
11.2450 |
16.2052 |
|
-6.2868 |
-11.2456 |
16.2028 |
|
6.3457 |
-11.2493 |
16.1992 |
|
-5.2278 |
-15.2034 |
-4.7148 |
|
4.5847 |
-15.2004 |
-4.7162 |
(For x, y corrected coordinates, use SLAC data if available. If not, use IHEP data.)
Fiducial – Corrected Coordinates |
z |
x |
y |
(in) |
(in) |
(in) |
|
TB1 |
|
|
|
TB2 |
|
|
|
TB3 |
|
|
|
TB4 |
|
|
|
TB5 |
|
|
|
TB6 |
|
|
|
Check Measurements:
Rod |
xmeasured |
xnominal |
ymeasured |
ynominal |
10.5003 |
10.5 in |
14.8063 |
14.8 in |
|
10.4995 |
10.5 in |
14.8064 |
14.8 in |
|
-10.5004 |
-10.5 in |
14.8079 |
14.8 in |
|
-10.5015 |
-10.5 in |
14.8076 |
14.8 in |
Cylinder at Different Positions
Position 1 (x,y)=(0,0) |
x (in) |
y (in) |
0.0009 |
-0.0002 |
|
0.0012 |
-0.0002 |
|
0.0003 |
-0.0007 |
Approval __________________