Quadrupole Magnet Checks

 

34Q-041

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 10/11/2001

 

 34Q-041

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-6.3030

 11.2376

 16.1958

 

 

 

 

 

 

 

TB2

 6.3300

 11.2415

 16.2039

 

 

 

 

 

 

 

TB3

-6.3215

-11.2451

 16.2028

 

 

Offset:

 

 

 

 

TB4

 6.3323

-11.2431

 16.1993

 

 

0.0000

 inches

 

 

 

TB5

-5.2100

-15.2003

-4.8080

 

 

 

 

 

 

 

TB6

 4.6199

-15.2001

-4.8435

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0001

 0.0004

Position 2

 0.0015

-0.0001

Position 3

 0.0012

-0.0010

Position 4

-0.0001

-0.0006

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0003

-0.0001

Position 1 (2nd check)

 0.0004

-0.0001

Position 1 (3rd check)

-0.0007

-0.0011

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.024

Loc 2: 1.024

Loc 2: 1.024

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 34Q-041

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 10/11/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
     

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-6.3030

11.2376

16.1958

TB2

6.3300

11.2415

16.2039

TB3

-6.3215

-11.2451

16.2028

TB4

6.3323

-11.2431

16.1993

TB5

-5.2100

-15.2003

-4.8080

TB6

4.6199

-15.2001

-4.8435

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5005

10.5 in

 14.8061

14.8 in

R2

 10.4977

10.5 in

 14.8082

14.8 in

R3

-10.4984

-10.5 in

 14.8082

14.8 in

R4

-10.5018

-10.5 in

 14.8067

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0016

-0.0004

Position 3

 0.0013

-0.0013

Position 4

 0.0000

-0.0010

Approval __________________