Quadrupole Magnet Checks

 

34Q-036

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 9/5/2001

 

 34Q-036

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Redid tip # 5 calibration.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-6.3151

 11.2141

 16.1996

 

 

 

 

 

 

 

TB2

 6.2973

 11.2521

 16.2017

 

 

 

 

 

 

 

TB3

-6.2974

-11.2319

 16.2028

 

 

Offset:

 

 

 

 

TB4

 6.2944

-11.2355

 16.1994

 

 

0.0000

 inches

 

 

 

TB5

-5.2285

-15.1998

-4.8170

 

 

 

 

 

 

 

TB6

 4.6201

-15.1996

-4.7990

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0006

 0.0000

Position 2

 0.0019

-0.0003

Position 3

 0.0017

-0.0009

Position 4

 0.0008

-0.0006

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0009

-0.0015

Position 1 (2nd check)

 0.0004

-0.0017

Position 1 (3rd check)

 0.0008

-0.0013

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.024

Loc 2: 1.023

Loc 2: 1.024

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 34Q-036

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 9/5/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Redid tip # 5 calibration.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-6.3151

11.2141

16.1996

TB2

6.2973

11.2521

16.2017

TB3

-6.2974

-11.2319

16.2028

TB4

6.2944

-11.2355

16.1994

TB5

-5.2285

-15.1998

-4.8170

TB6

4.6201

-15.1996

-4.7990

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5004

10.5 in

 14.8093

14.8 in

R2

 10.4972

10.5 in

 14.8059

14.8 in

R3

-10.4995

-10.5 in

 14.8088

14.8 in

R4

-10.5009

-10.5 in

 14.8052

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0013

-0.0003

Position 3

 0.0011

-0.0010

Position 4

 0.0002

-0.0006

Approval __________________