Sextupole Magnet Checks

 

 25S-73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 9/17/2001

 

 25S-73

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-4.3176

 4.2155

 15.5069

 

 

 

 

 

 

 

TB2

 4.3586

 4.1859

 15.5115

 

 

 

 

 

 

 

TB3

-4.4153

-10.5314

 12.5168

 

 

Offset:

 

 

 

 

TB4

 3.4169

-10.5289

 12.5181

 

 

0.0000

 inches

 

 

 

TB5

-4.4807

-15.0642

 0.0725

 

 

 

 

 

 

 

TB6

 4.4324

-15.0588

 0.0216

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0001

 0.0003

Position 2

-0.0006

-0.0008

Position 3

 0.0037

-0.0008

Position 4

 0.0046

-0.0019

Position 5

 0.0065

 0.0009

Position 6

-0.0001

 0.0011

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0018

 0.0000

Position 1 (2nd check)

 0.0020

 0.0001

Position 1 (3rd check)

 0.0022

-0.0005

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.068

Loc 1: 1.070

Loc 2: 1.072

Loc 2: 1.073

Loc 3: 1.072

Loc 3: 1.073

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 25S-73

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 9/17/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
     

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-4.3176

4.2155

15.5069

TB2

4.3586

4.1859

15.5115

TB3

-4.4153

-10.5314

12.5168

TB4

3.4169

-10.5289

12.5181

TB5

-4.4807

-15.0642

0.0725

TB6

4.4324

-15.0588

0.0216

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0007

-0.0011

Position 3

 0.0036

-0.0011

Position 4

 0.0045

-0.0022

Position 5

 0.0064

 0.0006

Position 6

-0.0002

 0.0008

Approval ________________________