Sextupole Magnet Checks

 

 25S-72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 8/13/2001

 

 25S-72

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-4.3717

 4.1991

 15.5017

 

 

 

 

 

 

 

TB2

 4.3190

 4.2019

 15.5026

 

 

 

 

 

 

 

TB3

-4.4191

-10.5307

 12.5179

 

 

Offset:

 

 

 

 

TB4

 3.4616

-10.5198

 12.5238

 

 

0.0000

 inches

 

 

 

TB5

-4.6036

-15.0607

 0.0738

 

 

 

 

 

 

 

TB6

 4.5290

-15.0627

 0.0769

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0001

 0.0001

Position 2

-0.0039

-0.0056

Position 3

 0.0043

-0.0060

Position 4

 0.0022

-0.0032

Position 5

 0.0033

-0.0012

Position 6

 0.0012

-0.0012

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0020

-0.0004

Position 1 (2nd check)

 0.0022

-0.0002

Position 1 (3rd check)

 0.0024

-0.0005

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.066

Loc 1: 1.065

Loc 2: 1.072

Loc 2: 1.073

Loc 3: 1.070

Loc 3: 1.073

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 25S-72

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 8/13/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
     

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-4.3717

4.1991

15.5017

TB2

4.3190

4.2019

15.5026

TB3

-4.4191

-10.5307

12.5179

TB4

3.4616

-10.5198

12.5238

TB5

-4.6036

-15.0607

0.0738

TB6

4.5290

-15.0627

0.0769

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0041

-0.0057

Position 3

 0.0042

-0.0061

Position 4

 0.0021

-0.0033

Position 5

 0.0032

-0.0013

Position 6

 0.0011

-0.0013

Approval ________________________