Sextupole Magnet Checks

 

 25S-63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 11/13/2001

 

 25S-63

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-4.5401

 4.1733

 15.5121

 

 

 

 

 

 

 

TB2

 4.5109

 4.1990

 15.5124

 

 

 

 

 

 

 

TB3

-4.4029

-10.4882

 12.5446

 

 

Offset:

 

 

 

 

TB4

 3.4945

-10.4889

 12.5385

 

 

0.0000

 inches

 

 

 

TB5

-4.5330

-15.0628

 0.0174

 

 

 

 

 

 

 

TB6

 4.5548

-15.0618

 0.0100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0003

 0.0000

Position 2

 0.0020

 0.0026

Position 3

-0.0045

 0.0027

Position 4

-0.0006

-0.0046

Position 5

 0.0034

 0.0019

Position 6

-0.0002

 0.0015

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0021

 0.0005

Position 1 (2nd check)

 0.0025

-0.0004

Position 1 (3rd check)

 0.0026

 0.0000

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.070

Loc 1: 1.072

Loc 2: 1.068

Loc 2: 1.071

Loc 3: 1.068

Loc 3: 1.068

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 25S-63

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 11/13/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
     

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-4.5401

4.1733

15.5121

TB2

4.5109

4.1990

15.5124

TB3

-4.4029

-10.4882

12.5446

TB4

3.4945

-10.4889

12.5385

TB5

-4.5330

-15.0628

0.0174

TB6

4.5548

-15.0618

0.0100

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0017

 0.0026

Position 3

-0.0048

 0.0027

Position 4

-0.0009

-0.0046

Position 5

 0.0031

 0.0019

Position 6

-0.0005

 0.0015

Approval ________________________