Sextupole Magnet Checks

 

 25S-52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 6/11/2001

 

 25S-52

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Bad data for D/S 2D line.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-4.3324

 4.2178

 15.5048

 

 

 

 

 

 

 

TB2

 4.3014

 4.2060

 15.5088

 

 

 

 

 

 

 

TB3

-4.3842

-10.5158

 12.5289

 

 

Offset:

 

 

 

 

TB4

 3.4612

-10.5129

 12.5313

 

 

0.0000

 inches

 

 

 

TB5

-4.2666

-15.0633

 0.0420

 

 

 

 

 

 

 

TB6

 4.2528

-15.0633

-0.1663

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

-0.0002

 0.0002

Position 2

-0.0027

-0.0044

Position 3

 0.0004

-0.0035

Position 4

 0.0013

-0.0061

Position 5

 0.0031

-0.0035

Position 6

 0.0025

-0.0035

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0022

 0.0001

Position 1 (2nd check)

 0.0021

 0.0004

Position 1 (3rd check)

 0.0020

 0.0007

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.064

Loc 1: 1.069

Loc 2: 1.075

Loc 2: 1.073

Loc 3: 1.068

Loc 3: 1.065

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 25S-52

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 6/11/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
Bad data for D/S 2D line.

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-4.3324

4.2178

15.5048

TB2

4.3014

4.2060

15.5088

TB3

-4.3842

-10.5158

12.5289

TB4

3.4612

-10.5129

12.5313

TB5

-4.2666

-15.0633

0.0420

TB6

4.2528

-15.0633

-0.1663

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0025

-0.0046

Position 3

 0.0006

-0.0037

Position 4

 0.0015

-0.0063

Position 5

 0.0033

-0.0037

Position 6

 0.0027

-0.0037

Approval ________________________