Sextupole Magnet Checks

 

 21S-37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 12/19/2001

 

 21S-37

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Remeasured U/S position 1 3 piece mandrel check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-3.7014

 4.2185

 15.5111

 

 

 

 

 

 

 

TB2

 3.6715

 4.2563

 15.5125

 

 

 

 

 

 

 

TB3

-3.6313

-10.5022

 12.5384

 

 

Offset:

 

 

 

 

TB4

 2.3135

-10.5380

 12.5161

 

 

0.0000

 inches

 

 

 

TB5

-3.8258

-15.0631

 0.0163

 

 

 

 

 

 

 

TB6

 3.7536

-15.0619

 0.0220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0000

 0.0001

Position 2

 0.0015

 0.0032

Position 3

 0.0000

 0.0018

Position 4

 0.0025

-0.0020

Position 5

 0.0045

 0.0013

Position 6

-0.0001

 0.0006

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0314

 0.1297

Position 1 (2nd check)

 0.0033

-0.0017

Position 1 (3rd check)

 0.0013

 0.0008

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.070

Loc 1: 1.070

Loc 2: 1.075

Loc 2: 1.070

Loc 3: 1.069

Loc 3: 1.072

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 21S-37

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 12/19/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
Remeasured U/S position 1 3 piece mandrel check.

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-3.7014

4.2185

15.5111

TB2

3.6715

4.2563

15.5125

TB3

-3.6313

-10.5022

12.5384

TB4

2.3135

-10.5380

12.5161

TB5

-3.8258

-15.0631

0.0163

TB6

3.7536

-15.0619

0.0220

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0015

 0.0031

Position 3

 0.0000

 0.0017

Position 4

 0.0025

-0.0022

Position 5

 0.0045

 0.0011

Position 6

-0.0001

 0.0004

Approval ________________________