Sextupole Magnet Checks

 

 21S-27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 11/27/2001

 

 21S-27

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-3.4698

 4.2163

 15.5059

 

 

 

 

 

 

 

TB2

 3.5734

 4.2031

 15.5037

 

 

 

 

 

 

 

TB3

-3.6329

-10.5053

 12.5371

 

 

Offset:

 

 

 

 

TB4

 2.3495

-10.5136

 12.5320

 

 

0.0000

 inches

 

 

 

TB5

-3.7535

-15.0623

 0.0629

 

 

 

 

 

 

 

TB6

 3.7255

-15.0611

 0.0463

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0001

 0.0001

Position 2

-0.0011

-0.0022

Position 3

 0.0013

-0.0023

Position 4

 0.0020

-0.0033

Position 5

 0.0010

-0.0046

Position 6

 0.0030

-0.0051

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0023

-0.0006

Position 1 (2nd check)

 0.0020

-0.0005

Position 1 (3rd check)

 0.0021

-0.0007

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.070

Loc 1: 1.071

Loc 2: 1.071

Loc 2: 1.071

Loc 3: 1.069

Loc 3: 1.069

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 21S-27

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 11/27/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
     

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-3.4698

4.2163

15.5059

TB2

3.5734

4.2031

15.5037

TB3

-3.6329

-10.5053

12.5371

TB4

2.3495

-10.5136

12.5320

TB5

-3.7535

-15.0623

0.0629

TB6

3.7255

-15.0611

0.0463

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0012

-0.0023

Position 3

 0.0012

-0.0024

Position 4

 0.0019

-0.0034

Position 5

 0.0009

-0.0047

Position 6

 0.0028

-0.0053

Approval ________________________