Sextupole Magnet Checks

 

 21S-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 1/2/2002

 

 21S-14

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Remeasured U/S position 5 one piece mandrel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-3.6586

 4.2138

 15.5123

 

 

 

 

 

 

 

TB2

 3.6399

 4.2028

 15.5113

 

 

 

 

 

 

 

TB3

-3.6291

-10.4960

 12.5398

 

 

Offset:

 

 

 

 

TB4

 2.2671

-10.5312

 12.5197

 

 

0.0000

 inches

 

 

 

TB5

-3.7331

-15.0624

 0.0162

 

 

 

 

 

 

 

TB6

 3.7622

-15.0611

-0.0013

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0002

-0.0003

Position 2

 0.0022

 0.0039

Position 3

 0.0024

 0.0036

Position 4

 0.0012

 0.0062

Position 5

-0.0004

 0.0021

Position 6

-0.0014

 0.0025

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0021

-0.0007

Position 1 (2nd check)

 0.0022

 0.0001

Position 1 (3rd check)

 0.0027

-0.0016

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.072

Loc 1: 1.070

Loc 2: 1.067

Loc 2: 1.068

Loc 3: 1.072

Loc 3: 1.072

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 21S-14

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 1/2/2002    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
Remeasured U/S position 5 one piece mandrel.

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-3.6586

4.2138

15.5123

TB2

3.6399

4.2028

15.5113

TB3

-3.6291

-10.4960

12.5398

TB4

2.2671

-10.5312

12.5197

TB5

-3.7331

-15.0624

0.0162

TB6

3.7622

-15.0611

-0.0013

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0020

 0.0042

Position 3

 0.0023

 0.0039

Position 4

 0.0010

 0.0065

Position 5

-0.0005

 0.0024

Position 6

-0.0016

 0.0027

Approval ________________________