Quadrupole Magnet Checks

 

15Q-030

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 9/5/2001

 

 15Q-030

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Redid VG # 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-2.5627

 11.2258

 16.1975

 

 

 

 

 

 

 

TB2

 2.5604

 11.2361

 16.1991

 

 

 

 

 

 

 

TB3

-2.5600

-11.2288

 16.1966

 

 

Offset:

 

 

 

 

TB4

 2.5707

-11.2527

 16.1981

 

 

0.0000

 inches

 

 

 

TB5

-1.4653

-15.1984

-4.8201

 

 

 

 

 

 

 

TB6

 2.4407

-15.1993

-4.8547

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0000

-0.0004

Position 2

 0.0028

-0.0017

Position 3

 0.0017

-0.0037

Position 4

-0.0002

-0.0029

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0010

-0.0021

Position 1 (2nd check)

 0.0010

-0.0019

Position 1 (3rd check)

 0.0011

-0.0018

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.024

Loc 2: 1.023

Loc 2: 1.023

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 15Q-030

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 9/5/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Redid VG # 1.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-2.5627

11.2258

16.1975

TB2

2.5604

11.2361

16.1991

TB3

-2.5600

-11.2288

16.1966

TB4

2.5707

-11.2527

16.1981

TB5

-1.4653

-15.1984

-4.8201

TB6

2.4407

-15.1993

-4.8547

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5015

10.5 in

 14.8077

14.8 in

R2

 10.4982

10.5 in

 14.8047

14.8 in

R3

-10.5018

-10.5 in

 14.8051

14.8 in

R4

-10.5021

-10.5 in

 14.8039

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0027

-0.0014

Position 3

 0.0017

-0.0033

Position 4

-0.0003

-0.0026

Approval __________________