Quadrupole Magnet Checks

 

15Q-026

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 9/7/2001

 

 15Q-026

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Redid D/S position 4 mandrel. Redid D/S 3 piece mandrel position 1 check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-2.5679

 11.2496

 16.1972

 

 

 

 

 

 

 

TB2

 2.5465

 11.2441

 16.2010

 

 

 

 

 

 

 

TB3

-2.5524

-11.2321

 16.2002

 

 

Offset:

 

 

 

 

TB4

 2.5602

-11.2435

 16.2004

 

 

0.0000

 inches

 

 

 

TB5

-1.4655

-15.1994

-4.7900

 

 

 

 

 

 

 

TB6

 2.4397

-15.1996

-4.8023

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

Quadrupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0000

 0.0002

Position 2

 0.0027

-0.0012

Position 3

 0.0020

-0.0036

Position 4

-0.0011

-0.0021

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0006

-0.0016

Position 1 (2nd check)

-0.0066

 0.1614

Position 1 (3rd check)

-0.0001

-0.0048

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

 

Quadrupole Gap Measurement Checks

 

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.023

Loc 1: 1.023

Loc 2: 1.023

Loc 2: 1.023

 

Approval __________________


 

 

 

 

 

 

Quadrupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 15Q-026

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at:  Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 9/7/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment
Redid D/S position 4 mandrel. Redid D/S 3 piece mandrel position 1 check.

 

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-2.5679

11.2496

16.1972

TB2

2.5465

11.2441

16.2010

TB3

-2.5524

-11.2321

16.2002

TB4

2.5602

-11.2435

16.2004

TB5

-1.4655

-15.1994

-4.7900

TB6

2.4397

-15.1996

-4.8023

 (For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Rod

xmeasured

xnominal

ymeasured

ynominal

R1

 10.5001

10.5 in

 14.8059

14.8 in

R2

 10.5003

10.5 in

 14.8066

14.8 in

R3

-10.4982

-10.5 in

 14.8082

14.8 in

R4

-10.4990

-10.5 in

 14.8064

14.8 in

Cylinder at Different Positions

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

 0.0027

-0.0014

Position 3

 0.0019

-0.0038

Position 4

-0.0011

-0.0023

Approval __________________