Sextupole Magnet Checks

 

 25S-48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

Magnet:

 

 

 

Operator(s):

 

 

 

 

 7/9/2001

 

 25S-48

 

 

 

 Michael Rogers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 Only the Tooling Ball values are correct. We are going to be redoing this one. Can not find the computer file for this sextupole.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic Fiducial Coordinates: (inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiducial

Z

X

Y

 

 

 

 

 

 

 

TB1

-4.2429

 4.2039

 15.5069

 

 

 

 

 

 

 

TB2

 4.2839

 4.2191

 15.5102

 

 

 

 

 

 

 

TB3

-4.3492

-10.5447

 12.5140

 

 

Offset:

 

 

 

 

TB4

 3.5100

-10.5235

 12.5374

 

 

0.0000

 inches

 

 

 

TB5

-4.1956

-15.0617

 0.1222

 

 

 

 

 

 

 

TB6

 4.2069

-15.0647

 0.1797

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

 

 

 

 

 

 

 

 

 

Fiducial values based on the measured mechanical center line.

 

 

 

 

 

 

 

 

 

 

 

 


Sextupole Mechanical Centerline Checks:

 

Mandrel Check (4 Positions):

X (in)

Y (in)

Position 1

 0.0001

 0.0002

Position 2

-0.0005

-0.0009

Position 3

 0.0031

 0.0002

Position 4

 0.0029

 0.0009

Position 5

 0.0020

-0.0002

Position 6

 0.0004

-0.0005

Mandrel Check (Position 1):

X (in)

Y (in)

Position 1 (1st check)

 0.0025

 0.0005

Position 1 (2nd check)

 0.0021

-0.0005

Position 1 (3rd check)

 0.0021

-0.0008

Position 1 (4th check if necc)

NA

NA

Position 1 (5th check if necc)

NA

NA

 

 

 

 

 

 

Sextupole Gap Measurement Checks

 

 

Gap Measurements:

 

Upstream (in)

Downstream (in)

Loc 1: 1.070

Loc 1: 1.069

Loc 2: 1.070

Loc 2: 1.071

Loc 3: 1.071

Loc 3: 1.072

Approval ________________________


 

 

Sextupole Magnet Fiducialization Traveller

Approval must be obtained before removing the magnet from the test stand. 

Magnetic Measurements Approval by – Jack Tanabe or Tony King.

Magnet Serial Number 25S-48

IHEP Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

SLAC Magnetic Measurements Operator: ____________   Date:_____________

Measured Magnetic Center Offset  Dx =__________ mm  Dy =___________ mm  

Measured at: Integrated Field:  ____________ T-m @ Current_____________ Amps

Fiducialization:

Date: 7/9/2001    Ambient Temperature ______________ deg. C. 

Operator(s)  Michael Rogers

Comment 
Only the Tooling Ball values are correct. We are going to be redoing this one. Can not find the computer file for this sextupole.

Fiducial – Measured

Coordinates

z

x

y

(in)

(in)

(in)

TB1

-4.2429

4.2039

15.5069

TB2

4.2839

4.2191

15.5102

TB3

-4.3492

-10.5447

12.5140

TB4

3.5100

-10.5235

12.5374

TB5

-4.1956

-15.0617

0.1222

TB6

4.2069

-15.0647

0.1797

(For x, y corrected coordinates, use SLAC data if available.  If not, use IHEP data.)

Fiducial – Corrected

Coordinates

z

x

y

(in)

(in)

(in)

TB1

 

 

 

TB2

 

 

 

TB3

 

 

 

TB4

 

 

 

TB5

 

 

 

TB6

 

 

 

Check Measurements:

Flat Center

xmeasured

xnominal

ymeasured

ynominal

Upstream

 

0.0 in

 

12.8 in

Downstream

 

0.0 in

 

12.8 in

 

Position 1 (x,y)=(0,0)

x (in)

y (in)

Position 2

-0.0006

-0.0011

Position 3

 0.0030

 0.0000

Position 4

 0.0028

 0.0006

Position 5

 0.0019

-0.0004

Position 6

 0.0003

-0.0007

Approval ________________________